Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements

Product Details
Customization: Available
Type: Insulated
Conductor Type: Stranded
Still deciding? Get samples of US$ 10/Meter
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
107
Year of Establishment
2000-11-03
  • Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements
  • Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements
  • Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements
  • Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements
  • Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements
  • Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements
Find Similar Products
  • Overview
  • Product Description
  • Application Area
  • Manufacturing Shop
  • Certifications
  • Packaging & Shipping
  • Company Profile
  • Our Advantages
Overview

Basic Info.

Model NO.
FLALY, FLAL2G, FLAL2X, FLAL91X
Application
Internal Connection Wiring Between Battery and Eng
Conductor Material
Al
Insulation Material
PVC
Material Shape
Round Wire
Range of Application
Internal Connection Wiring Between Battery and Eng
Certification
ISO9001, CCC, RoHS, VDE, Itf16949
Brand
Yuanda
Temperature Range
105c
Color
as Requirements
Lead Time
20 Days
MOQ
5000m
Transport Package
Pallet/Carton/Tray/Reel
Specification
6-160mm2
Trademark
Yuanda
Origin
Wuxi, China
HS Code
8544491100
Production Capacity
1000km/Day

Product Description



 
Product Description

 


Aluminum Conductor Battery Cable Meeting ISO6722-2/GMW17085 Requirements                                                
                                              

Type:FLALY, FLAL2G, FLAL2X, FLAL91X                                                      
Nominal Voltage: 60V                                                   
Temperature Range: FLALY(-40ºC~+105ºC)
                                  FLAL2G(-40ºC~+200ºC)
                                  FLAL2X(-40ºC~+125ºC)
                                  FLAL91X(-40ºC~+150ºC)                                              
Conductor: Aluminum                                                 
Insulation: FLALY: -40ºC~+105ºC PVC 
                 FLAL2G: -40ºC~+200ºC SIR
                 FLAL2X: -40ºC~+125ºC XLPO
                 FLAL91X: -40ºC~+150ºC XLPO"                                                
Standard: ISO 6722-2/GMW 17085                                                 
Application: Internal connection wiring between battery and engine, or other circuits in electric vehicles.
 
Conductor Insulation Max. resistence at 20ºC
Ω/km
Thick-wall Thin-wall

Nominal Cross Section
(mm²)
Structure B
NO./mm
Structure C
No./mm
Diameter
(mm)
Nominal Thickness
(mm)
Cable Outer Diameter
(mm)
Nominal Thickness
(mm)
Cable Outer Diameter
(mm)
6 45/0.42 70/0.33 3.4 0.8 5 0.4 4.3 5.23
8 59/0.42 98/0.33 4.3 0.8 5.9 0.4 5 3.97
10 50/0.52 126/0.33 4.5 1 6.5 0.6 6 3.03
12 60/0.52 154/0.33 5.4 1 7.4 0.6 6.5 2.53
16 78/0.52 209/0.33 5.8 1 8.3 0.65 7.2 1.93
20 95/0.52 247/0.33 6.9 1.1 9.1 0.65 7.8 1.59
25 122/0.52 323/0.33 7.2 1.3 10.4 0.65 8.7 1.24
30 141/0.52 361/0.33 8.3 1.3 10.9 0.8 9.6 1.08
35 172/0.52 456/0.33 8.5 1.3 11.6 0.8 10.4 0.878
40 193/0.52 494/0.33 9.6 1.4 12.4 0.9 11.1 0.788
50 247/0.52 646/0.33 10.5 1.5 13.5 0.9 12.2 0.613
60 289/0.52 741/0.33 11.6 1.5 14.6 1 13.3 0.525
70 351/0.52 855/0.33 12.5 1.5 15.5 1 14.4 0.432
85 420/0.52 1064/0.33 13.6 1.6 16.8 1.1 15.8 0.365
90 463/0.52 1178/0.33 14.8 1.6 18 1.1 16.7 0.327
120 305/0.72 / 16.5 1.6 19.7 / / 0.255
160 398/0.72 / 19 1.6 22.5 / / 0.195
                   
           
Application Area


Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements


 
Manufacturing Shop
Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements
Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements
Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements

 

Certifications

We have the certifications  of UL, VDE, CCC, ISO9001, IATF 16949.

Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements
 

Packaging & Shipping

 

Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements
Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements
Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements


 

Company Profile

Jiangyin Yuanda Electrical Material Co., Ltd. is a professional manufacturer, and our main products include
A. Series of automotive cables which can meet various standards , like ISO, SAE, JASO, JB/T, VW, LV, GMW and etc. ; 
B. RF, RG series of coaxial cables with abroad application in cellphone , laptop , router , 5G/6G , war industry , smart car and etc. for communication ;
C. UL, VDE, CCC verified , PVC/cross-linked polyolefin/silicone rubber/fluoroplastic insulated series of household electric appliance wires ;
D. Heat resistant silicone rubber sleeves with (or without) fiberglass braid , widely used in household appliances, motors, vehicles and etc. ;
E. Special cables applicable to urban orbitals, photovoltaic systems, wind power generation, space navigation and etc..

mmai
n products includeain products includemain products include
main products include

Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements
Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements
Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements



 

Our Advantages

Yuanda have abundant technical strength, advanced equipment ,functional testing facilities and good quality-ensuring systems . We have acquired the certificates of IATF 16949,ISO 9001,ISO 14001,OHSAS 18001 for automotive cables and communication cables . Series of silicone rubber, fluorine plastic, crosslinked polyolefin electronic wires and sleeves are certified by UL,VDE and CCC.

Especially our aluminum conductor cable , new energy high-voltage shield cable , and some coaxial cables used in automotive , enjoy high popularity in automotive industry. With high-qualify products, reasonable price and splendid after-sales service, our products supporting customers are exported to the world.
 

Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements
Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements
Flal2g Aluminum Conductor Battery Cable Meeting ISO6722-2 Requirements

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier