• FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements
  • FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements
  • FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements
  • FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements
  • FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements
  • FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements

FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements

Type: Insulated
Conductor Type: Stranded
Application: Internal Wiring
Conductor Material: Bare Copper
Insulation Material: Xlpo
Material Shape: Round Wire
Samples:
US$ 10/Meter 1 Meter(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Application Area
  • Manufacturing Shop
  • Certifications
  • Packaging & Shipping
  • Company Profile
  • Our Advantages
Overview

Basic Info.

Model NO.
FLRY,FLR9Y,FLR4G,FLR11Y,FLR31Y,FLR2X,FLR91X,FLR6Y,
Range of Application
Internal Wiring
Certification
ISO9001, CCC, RoHS, Itf16949
Brand
Yuanda
Temperature Range
105c
Color
as Requirements
Lead Time
20 Days
MOQ
5000m
Transport Package
Pallet/Carton/Tray/Reel
Specification
4-120mm2
Trademark
Yuanda
Origin
Wuxi, China
HS Code
8544491100
Production Capacity
1000km/Day

Product Description



 
Product Description

 


Single Core Low-voltage Unshielded Cable Meeting LV112-1 Requirements                                                    
                                              

Type: FLRY,FLR9Y,FLR4G,FLR11Y,FLR31Y,FLR2X,FLR91X,FLR6Y,FLR7Y,FLR51Y
Type: FLY,FL9Y,FL4G,FL11Y,FL31Y,FL2X,FL91X,FL2G
Nominal Voltage: 60V
Temperature Range: -40 C-+105,125,150,175,200,250 C
Conductor: Bare Copper
Insulation: 105-PVC,PP,EVA; 125-PVC,PUR,TPE,XLPO; 150-XLPO; 175-ETFE; 200-SIR,FEP; 250-PFA
Standard:LV 112-1
Application: Internal connection wiring for circuits in electric vehicles.
 
 
 Conductor Insulation Max. resistance at 20ºC
Ω/km
Nominal Cross Section
(mm2)
Conductor Structure No./mm Conductor Diameter (mm) max Thin-wall Thick-wall
Thickness min Outer Diameter (mm) Thickness min Outer Diameter (mm)
4 120/0.20 2.75 0.32 3.7 0.64 4.4 4.71
56/0.30
6 183/0.20 3.4 0.32 4.3 0.64 5.0 3.14
84/0.30
10 305/0.20 4.5 0.48 5.8 0.8 6.5 1.82
80/0.40
16 500/0.20 6.3 0.52 7.0 0.8 7.5 1.16
126/0.40
25 790/0.20 7.8 0.64 8.8 1.04 9.6 0.743
196/0.40
35 1090/0.20 9.0 0.8 10.5 1.04 10.9 0.527
276/0.40
50 1600/0.20 10.5 / / 1.2 12.8 0.368
396/0.40
70 2175/0.20 12.5 / / 1.2 14.6 0.259
360/0.50
95 3000/0.20 14.8 / / 1.28 17.0 0.196
475/0.50
120 3700/0.20 16.5 / / 1.28 18.3 0.153
608/0.50

           
Application Area


FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements


 
Manufacturing Shop
FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements
FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements
FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements

 

Certifications

We have the certifications  of UL, VDE, CCC, ISO9001, IATF 16949.

FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements
 

Packaging & Shipping

 

FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements
FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements
FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements


 

Company Profile

Jiangyin Yuanda Electrical Material Co., Ltd. is a professional manufacturer, and our main products include
A. Series of automotive cables which can meet various standards , like ISO, SAE, JASO, JB/T, VW, LV, GMW and etc. ; 
B. RF, RG series of coaxial cables with abroad application in cellphone , laptop , router , 5G/6G , war industry , smart car and etc. for communication ;
C. UL, VDE, CCC verified , PVC/cross-linked polyolefin/silicone rubber/fluoroplastic insulated series of household electric appliance wires ;
D. Heat resistant silicone rubber sleeves with (or without) fiberglass braid , widely used in household appliances, motors, vehicles and etc. ;
E. Special cables applicable to urban orbitals, photovoltaic systems, wind power generation, space navigation and etc..

mmai
n products includeain products includemain products include
main products include

FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements
FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements
FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements



 

Our Advantages

Yuanda have abundant technical strength, advanced equipment ,functional testing facilities and good quality-ensuring systems . We have acquired the certificates of IATF 16949,ISO 9001,ISO 14001,OHSAS 18001 for automotive cables and communication cables . Series of silicone rubber, fluorine plastic, crosslinked polyolefin electronic wires and sleeves are certified by UL,VDE and CCC.

Especially our aluminum conductor cable , new energy high-voltage shield cable , and some coaxial cables used in automotive , enjoy high popularity in automotive industry. With high-qualify products, reasonable price and splendid after-sales service, our products supporting customers are exported to the world.
 

FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements
FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements
FLRY Single Core Low-Voltage Unshielded Cable Meeting LV112-1 Requirements

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now